  • STEEL TANKS


    Pump Tank Stations

    Steel Reservoirs from 250 to 3600 Gallons

    Temptek pump tank stations are a two part system, a reservoir and pumping station with one or two pumps. The assembly is designed circulate a fluid medium (typically water or water-glycol solution) through several process applications through out your plant. Pump tank stations work with cooling tower systems or chilling systems to make a central water system.

    • Capacities from 250 – 3600 Gallons
    • Tower or Chilled Water Systems
    • Pumps from 2 – 60 HP
    • Flows from 40 – 1250 GPM
    • 7 ga. Steel Reservoir
    • Mild or Stainless Steel

    The PT Series pump tank station is very space efficient. It uses the vertical dimension for water storage, and uses an integral pump platform deck to minimize floor space footprint. The high flow, high turbulent pumps offer maximum heat transfer across the process.
    This pump tank is designed and engineered for round-the-clock operations with minimal service, providing maximum return on investment.

    PT Series pump tank stations are great for start-up installations and expansions of existing systems.
    Systems can be customized to meet any need. Components are shipped loose and field assembled. All drawings are supplied for easy assembly. Available options can be factory
    assembed and wired. Consult factory for details.

    .

    TANK CONSTRUCTION
    • Sand blasted and epoxy coated 7 ga. mild steel assembly, welded
    • Stainless steel optional
    • Perimeter belting reinforcement
    • Drain valve
    • Overflow port
    • Hot / cold section partition (baffle)
    • Water-level control (float type)
    • Structural steel base
    • Pump platform decking
    • Flange pump connections
    • Multiple pump connections
    • Tank insulating on chilled water systems

    PUMPS
    • Centrifugal, motor driven
    • Bronze impeller
    • Suction service valve kit
    • Discharge service valve kit

    ELECTRICAL
    • Prewired magnetic pump motor starters
    • Nema 1 rated
    • Overload protection
    • Thermostat control of tower fan (where applicable)

    WARRANTY & SERVICE
    • 1 year on parts & labor
    • Nationwide network of service contractors

    OPTIONS
    • Standby pump and discharge manifold with isolation valves
    • Prewired system control cabinet for starters and controls
    • Tank service lid
    • Tank insulation for chilled water applications
    • Shipped complete…not as a kit.
    • Pumps, valves, and starters are mounted and
    wired… set in a place and hit the switch.

    PT SPECIFICATIONS

    MODEL PT-275 PT-400 PT-600 PT-750 PT-1000 PT-1250 PT-1500 PT-2000 PT-2500 PT-3000
    WATER CAPACITY TO OVERFLOW 275 400 600 750 1000 1250 1500 2000 2500 3000
    WATER CAPACITY TOWER WATER 180 240 345 450 560 700 840 1120 1400 1625
    WATER CAPACITY CHILLED WATER 180 300 485 615 790 985 1185 1575 1930 2350
    CONNECTION WATER MAKE-UP 1″ NPT 1″ NPT 1″ NPT 1″ NPT 1″ NPT 1 1/4″ NPT 1 1/4″ NPT 1 1/4″ NPT 1 1/2″ NPT 1 1/2″ NPT
    CONNECTION TANK DRAIN 1 1/2″ NPT 1 1/2″ NPT 1 1/2″ NPT 1 1/2″ NPT 1 1/2″ NPT 1 1/2″ NPT 1 1/2″ NPT 1 1/2″ NPT 1 1/2″ NPT 1 1/2″ NPT
    CONNECTION TANK OVERFLOW 4″ NPT 4″ NPT 4″ NPT 4″ NPT 4″ NPT 4″ NPT 4″ NPT 6″ NPT 6″ NPT 6″ NPT
    DIMENSIONS: HEIGHT 55″ 55″ 67″ 79″ 79″ 79″ 79″ 79″ 79″ 79″
    DIMENSIONS: WIDTH 60″ 60″ 72″ 72″ 72″ 72″ 72″ 72″ 72″ 144″
    DIMENSIONS: DEPTH 24″ 36″ 36″ 36″ 48″ 60″ 72″ 96″ 120″ 72″
    DIMENSIONS: DEPTH WITH PUMP BASE 60″ 72″ 80″ 80″ 100″ 112″ 112″ 150″ 174″ 124″
    WEIGHT DRY 1625 LBS 1745 LBS 2300 LBS 2800 LBS 3250 LBS 4300 LBS 4500 LBS 4990 LBS 5480 LBS 6580 LBS
    WEIGHT OPERATING 3125 LBS 4245 LBS 6340 LBS 7920 LBS 9805 LBS 12505 LBS 14335 LBS 18060 LBS 21500 LBS 26085 LBS
    WEIGHT MAXIMUM 3915 LBS 5075 LBS 7295 LBS 9050 LBS 11580 LBS 14715 LBS 17000 LBS 21650 LBS 26300 LBS 31600 LBS
    WEIGHT SHIPPING 1725 LBS 1845 LBS 2400 LBS 2920 LBS 3370 LBS 4500 LBS 4700 LBS 5300 LBS 5700 LBS 6750 LBS

    P SERIES PUMP SPECIFICATIONS

    PROCESS / STANDBY PUMP MODEL PP-2 PP-3 PP-5 PP-7.5 PP-10 PP-15 PP-20 PP-25 PP-30 PP-40 PP-50 PP-60
    PUMP HP 2 3 5 7.5 10 15 20 25 30 40 50 60
    PUMP GPM / PSI 40 / 40 60 / 60 90 / 60 150 / 60 210 / 60 360 / 60 405 / 60 525 / 60 600 / 60 900 / 60 1100 / 60 1250 / 60
    FULL LOAD AMPS @ 230 / 3 / 60 6.8 9.6 15.2 22 28 42 54 68 84 104 130 154
    FULL LOAD AMPS @ 460 / 3 / 60 3.4 4.8 7.6 11 14 21 27 34 42 52 65 77

    TP SERIES PUMP SPECIFICATIONS

    TOWER / EVAPORATOR PUMP MODEL TP-2 TP-3 TP-5 TP-7.5 TP-10 TP-15 TP-20 TP-25 TP-30 TP-40
    PUMP HP 2 3 5 7.5 10 15 20 25 30 40
    PUMP GPM / PSI 60 / 30 90 / 30 210 / 30 255 / 30 405 / 30 525 / 30 810 / 30 900 / 30 1100 / 30 1750 / 30
    FULL LOAD AMPS @ 230 / 3 / 60 6.8 9.6 15.2 22 28 42 54 68 84 104
    FULL LOAD AMPS @ 460 / 3 / 60 3.4 4.8 7.6 11 14 21 27 34 42 52

  • Array ( [0] => new-equipment [1] => temp-controlchillers [2] => new-equipment [3] => temp-controlchillers )
  • POLYETHELYNE TANKS


    Pump Tank Stations

    Polyethylene Reservoirs from 450 to 3200 Gallons

    Temptek pump tank stations are a two part system, a reservoir and pumping station with one or two pumps. The assembly is designed circulate a fluid medium (typically water or water-glycol solution) through several process applications through out your plant. Pump tank stations work with cooling tower systems or chilling systems to make a central water system.

    • Capacities From 450 – 3200 Gallons
    • Tower or Chilled Water Systems
    • Pumps from 2 – 60 HP
    • Flows from 40 – 1250 GPM
    • Seamless Rotational Molded Reservoir
    • 10 Year Tank Warranty

    The PPT Series pump tank station is very space efficient. It uses the vertical dimension for water storage, and uses an integral pump platform deck to minimize floor space footprint. The high flow, high turbulent pumps offer maximum heat transfer across the process. The patent pending reservoir is a seamless, one piece rotationally molded polyethylene reservoir. This reservoir is rust and corrosive free, and will not degrade, regardless of water quality. Pump assemblies are mounted on a structural steel deck and attached to the tank via flexible connectors. This pump tank is designed and engineered for round-the-clock operations with minimal service, providing maximum return on investment.

    Components are shipped loose and field assembled.
    All drawings are supplied for easy assembly. Available options can be factory assembly and wired. Consult factory for details.

    TANK CONSTRUCTION
    • One piece, seemless, cylindrical shape reservoir
    • Rotationally molded linear low density polyethylene
    • Drain valve
    • Overflow port
    • Hot / cold section partition (baffle)
    • Temperature gauges for each partition
    • Water-level control (float type)
    • Flange pump connections
    • Multiple pump connections
    • Tank insulating on chilled water systems (optional)
    • Tank lid

    ELECTRICAL
    • Prewired magnetic pump motor starters
    • Nema 1 rated
    • Overload protection
    • Thermostat control of tower fan (where applicable)

    PUMPS
    • Structural steel deck for pump mounting
    • Flexible connections
    • Centrifugal, motor driven
    • Bronze impeller
    • Suction service valve kit
    • Discharge service valve kit

    WARRANTY & SERVICE
    • 10 year tank failure warranty
    • 1 year on mechanical components
    • Nationwide network of service contractors

    OPTIONS
    • Standby pump and discharge manifold with isolation valves
    • Prewired control cabinet for starters and controls
    • Mounting and wiring all components.

    PPT SERIES SPECIFICATIONS

    MODEL # PPT-450 PPT-850 PPT-1600 PPT-3200
    WATER CAPACITY TO OVERFLOW 450 850 1600 3200
    WATER CAPACITY TOWER WATER 225 425 800 1600
    WATER CAPACITY CHILLED WATER 350 675 1200 2400
    CONNECTION: WATER MAKE-UP 1″ NPT 1″ NPT 1″ NPT 1″ NPT
    CONNECTION: TANK DRAIN 1 1/2″ NPT 1 1/2″ NPT 1 1/2″ NPT 1 1/2 NPT
    CONNECTION: TANK OVERFLOW 4″ NPT 4″ NPT 6″ NPT 6″ NPT
    DIMENSION: HEIGHT 60″ 72″ 96″ 96″
    DIMENSION: WIDTH 48″ 60″ 72″ 160″
    DIMENSION: DEPTH 50″ 62″ 74″ 74″
    DIMENSION: DEPTH WITH PUMP BASE 36″ 36″ 48″ 48″
    WEIGHT DRY 860 LBS 1590 LBS 2243 LBS 4636 LBS
    WEIGHT OPERATING 2750 LBS 5160 LBS 8963 LBS 18076 LBS
    WEIGHT MAXIMUM 4640 LBS 8730 LBS 15683 LBS 31516 LBS
    WEIGHT SHIPPING 860 LBS 1590 LBS 2243 LBS 4636 LBS

    P SERIES PUMP SPECIFICATIONS

    PROCESS / STANDBY PUMP MODEL PP-2 PP-3 PP-5 PP-7.5 PP-10 PP-15 PP-20 PP-25 PP-30 PP-40 PP-50 PP-60
    PUMP HP 2 3 5 7.5 10 15 20 25 30 40 50 60
    PUMP GPM / PSI 40 / 40 60 / 60 90 / 60 150 / 60 210 / 60 360 / 60 405 / 60 525 / 60 600 / 60 900 / 60 1100 / 60 1250 / 60
    FULL LOAD AMPS @ 230 / 3 / 60 6.8 9.6 15.2 22 28 42 54 68 84 104 130 154
    FULL LOAD AMPS @ 460 / 3 / 60 3.4 4.8 7.6 11 14 21 27 34 42 52 65 77

    TP SERIES PUMP SPECIFICATIONS

    TOWER / EVAPORATOR PUMP MODEL TP-2 TP-3 TP-5 TP-7.5 TP-10 TP-15 TP-20 TP-25 TP-30 TP-40
    PUMP HP 2 3 5 7.5 10 15 20 25 30 40
    PUMP GPM / PSI 60 / 30 90 / 30 210 / 30 255 / 30 405 / 30 525 / 30 810 / 30 900 / 30 1100 / 30 1750 / 30
    FULL LOAD AMPS @ 230 / 3 / 60 6.8 9.6 15.2 22 28 42 54 68 84 104
    FULL LOAD AMPS @ 460 / 3 / 60 3.4 4.8 7.6 11 14 21 27 34 42 52
  • Array ( [0] => new-equipment [1] => temp-controlchillers [2] => new-equipment [3] => temp-controlchillers )
  • WATER COOLED 5 TO 180 TONS


    Water Cooled Central Chillers 5 to 180 Tons

    (Single Zone & Multizone – Digital Control)

    Process liquid chillers are designed to circulate a fluid medium (typically water, or a water-glycol solution) through a process application for cooling and can supply temperatures between 20° to 65°F. Central units provide enough capacity to serve multiple process applications. Generally, central liquid chillers are offered in capacities from 5 to 180 tons and can serve several process at once.

    Water cooled liquid chillers use a plant water supply source (tower water, city water, or well water) to dissipate process heat. Major benefits to water-cooled units are less capital expense and less maintenance.

    The MW Series central chiller provides precision temperature control from an economically affordable and reliable unit. Perfect for applications such as plastic injection molding, blow molding, extrusion and other industrial
    applications. Product features include:

    TEMPERATURE RANGE
    • 20° – 65°F

    REFRIGERANT ZONES
    • Hermetic scroll or rotary screw compressors
    • Liquid line solenoid valve
    • Refrigerant sight glass with moisture indicator
    • Thermostatic expansion valve
    • Brazed plate or shell & tube evaporator
    • Hot gas by-pass or unloading capacity control systems
    • Water-cooled condenser with regulator valve and single connection with manifold and isolation
    valves and removable heads
    • R410A or R407C refrigerant

    PRESSURE GAUGES:
    • Refrigerant high pressure
    • Refrigerant low pressure
    • Coolant pressure

    LIMIT DEVICES:
    • Refrigerant circuit:
    • high pressure limit
    • low pressure limit
    • evaporator flow limit
    • Instrument control circuit fuse

    ELECTRICAL:
    • Nema rated electrical cabinet
    • Fused pump motor starters
    • Fused compressor motor starters
    • Fused transformer
    • Power entry terminal block

    WARRANTY:
    • 1 year covering parts and labor

    INSTRUMENT

    CHILLER CONTROL INSTRUMENT:
    • Microprocessor based multizone controller
    • Intelligent zone boards
    • Each compressor staged individually
    • Large temperature display in °F or °C for to process and from process
    • Large setup display
    • Refrigerant circuit indicators per zone: probe, low flow, high pressure, low pressure,
    compressor, freezestat, capacity
    • Water circuit indicators: temperature deviation, low pressure, probe, phase
    • SPI communications interface
    • Selectable lead/lag mode
    • Audible and visual alarm (optional)

    MODEL CAPACITY COMPRESSORS REFRIDGERANT # ZONES GPM (3-PHASE) FL AMPS 230V / 460V CONNECTIONS DIMENSIONS WEIGHT
    MWD-5 5 TONS 1 – HERMETIC SCROLL R410A 1 13 25 @ 230V / 12.5 @ 460V 1 1/4″ NPT 52″ X 24″ X 62″ 450 LBS
    MWD-7.5 7.5 TONS 1 – HERMETIC SCROLL R410A 1 22 31 @ 230V / 16 @ 460V 1 1/4″ NPT 52″ X 24″ X 62″ 525 LBS
    MWD-10 10 TONS 1 – HERMETIC SCROLL R410A 1 28 43 @ 230V / 22 @ 460V 1 1/4″ NPT 52″ X 24″ X 62″ 545 LBS
    MWD-15 15 TONS 1 – HERMETIC SCROLL R410A 1 36 60 @ 230V / 30 @ 460V 2″ NPT 52″ X 24″ X 70″ 845 LBS
    MWD-20 20 TONS 2 – HERMETIC SCROLL R410A 1 47 84 @ 230V / 42 @ 460V 2″ NPT 52″ X 24″ X 70″ 885 LBS
    MWD-25 25 TONS 2 – HERMETIC SCROLL R407C 1 60 104 @ 230V / 52 @ 460V 2 1/2″ NPT 57″ X 29″ X 70″ 1040LBS
    MWD-30 30 TONS 2 – HERMETIC SCROLL R407C 1 72 120 @ 230V / 60 @ 460V 2 1/2″ NPT 57″ X 29″ X 70″ 1100 LBS
    MWD-40 40 TONS 1 – SCREW R407C 1 101 156 @ 230V / 78 @ 460V 2 1/2″ NPT 57″ X 36″ X 84″ 1200 LBS
    MWD-50 50 TONS 1 – SCREW R407C 1 120 216 @ 230V / 108 @ 460V 3″ NPT 57″ X 36″ X 84″ 1300 LBS
    MWD-60 60 TONS 1 – SCREW R407C 1 138 256 @ 230V / 128 @ 460V 3″ NPT 57″ X 36″ X 84″ 1400 LBS
    MWD-202 20 TONS 2 – HERMETIC SCROLL R407C 2 72 83 @ 230V / 39 @ 460V 2″ NPT 57″ X 48″ X 76″ 1200 LBS
    MWD-302 30 TONS 2 – HERMETIC SCROLL R407C 2 85 112 @ 230V / 56 @ 460V 2 1/2″ NPT 57″ X 48″ X 76″ 1800 LBS
    MWD-402 40 TONS 4 – HERMETIC SCROLL R407C 2 96 168 @ 230V / 84 @ 460V 2 1/2″ NPT 57″ X 48″ X 76″ 1900 LBS
    MWD-502 50 TONS 4 – HERMETIC SCROLL R407C 2 120 208 @ 230V / 104 @ 460V 3″ NPT 57″ X 52″ X 79″ 2200 LBS
    MWD-602 60 TONS 4 – HERMETIC SCROLL R407C 2 144 240 @ 230V / 120 @ 460V 3″ NPT 57″ X 52″ X 79″ 2350 LBS
    MWD-802 80 TONS 4 – HERMETIC SCROLL R407C 2 192 312 @ 230V / 156 @ 460V 4″ NPT 57″ X 72″ X 84″ 2600 LBS
    MWD-1002 100 TONS 2 – SCREW R407C 2 240 432 @ 230V / 216 @ 460V 4″ NPT 70″ X 90″ X 115″ 3450 LBS
    MWD-1202 120 TONS 2 – SCREW R407C 2 277 512 @ 230V / 266 @ 460V 4″ NPT 70″ X 90″ X 115″ 3700 LBS
    MWD-903 90 TONS 6 – HERMETIC SCROLL R407C 3 216 365 @ 230V / 180 @ 460V 4″ NPT 85″ X 73″ X 130″ 3300 LBS
    MWD-1203 120 TONS 3 – SCREW R407C 3 288 468 @ 230V / 234 @ 460V 4″ NPT 85″ X 73″ X 130″ 3600 LBS
    MWD-1503 150 TONS 3 – SCREW R407C 3 359 648 @ 230V / 324 @ 460V 6″ NPT 85″ X 73″ X 130″ 3900 LBS
    MWD-1803 180 TONS 3 – SCREW R407C 3 415 768 @ 230V / 384 @ 460V 6″ NPT 85″ X 73″ X 130″ 4200 LBS

  • Array ( [0] => new-equipment [1] => temp-controlchillers [2] => new-equipment [3] => temp-controlchillers )
  • WATER COOLED 5 TO 40 TONS


    Water Cooled Central Chillers 5 to 40 Tons

    (Single Zone – Thermostat Control)

    Process liquid chillers are designed to circulate a fluid medium (typically water, or a water-glycol solution) through a process application for cooling and can supply temperatures between 20° to 65°F. Central units provide enough capacity to serve multiple process applications. Generally, central liquid chillers are offered in capacities from 5 to 180 tons and can serve several process at once.

    Water cooled liquid chillers use a plant water supply source (tower water, city water, or well water) to dissipate process heat. Major benefits to water-cooled units are less capital expense and less maintenance.

    STANDARD FEATURES

    TEMPERATURE RANGE:
    • 20°F – 65°F

    FRAME CONSTRUCTION:
    • Galvanized steel frame
    • Galvanized enclosure panels
    • Castors – for portability
    • Standard NPT process fittings

    REFRIGERANT CIRCUITS:
    • Scroll compressor
    • Full component insulation
    • Air-cooled condenser with finned tubes
    • Centrifugalblower induced air flow
    • Filter-drier with replaceable core
    • Liquid line solenoid valve
    • Refrigerant sight glass with moisture indicator
    • Thermostatic expansion valve
    • Brazed plate evaporator
    • Capacity control (via hot gas
    bypass)

    ELECTRICAL:
    • Compressor motor starter
    • Fused transformer
    • NEMA rated electrical cabinet
    • Power entry terminal block

    SYSTEM LIMIT DEVICES:
    • High pressure limit
    • Low pressure limit
    • Coolant freezestat
    • Internal compressor overload
    • Control circuit fuse

    WARRANTY:
    • 1 year on parts and labor

    INSTRUMENT

    CF Series (standard instrument)
    • Continuous To Process temperature display
    • Selectable Setpoint temperature display
    • Illuminate ON/OFF power switch
    • Soft touch Setpoint selection keys
    • Bright and easy-to-read LCD Temperature display window
    • Machine Status Lights with Compressor and
    Capacity Control indication
    • Basic Machine Diagnostics with Refrigeration Fault
    indicating light

    ALL MODELS USE HERMETIC SCROLL COMPRESSORS

    MODEL CAPACITY COMPRESSOR HP REFRIDGERANT PUMP HP GPM PSI (3-PHASE) FL AMPS 230V / 460V CONNECTIONS DIMENSIONS WEIGHT
    CFD-5W 5.1 TONS 5 410A 2 12 52 30 @ 230V / 15 @ 460V 1 1/4″ NPT 40″ X 32″ X 40″ 655LBS
    CFD-7.5W 7.6 TONS 7.5 410A 2 19 48 40 @ 230V / 20 @ 460V 1 1/4″ NPT 40″ X 32″ X 40″ 740 LBS
    CFD-10W 10.5 TONS 10 410A 2 26 47 48 @ 230V / 24 @ 460V 1 1/4″ NPT 40″ X 32″ X 40″ 760 LBS
    CFD-15W 15 TONS 15 407C 3 36 55 68.4 @ 230V / 34.2 @ 460V 2″ NPT 57″ X 34″ X 80″ 1500 LBS
    CFD-20W 20 TONS 10 X 2 407C 3 48 50 78 @ 230V / 39 @ 460V 2″ NPT 57″ X 34″ X 80″ 1900 LBS
    CFD-25W 25 TONS 13 X 2 407C 5 60 59 106 @ 230V / 53 @ 460V 2″ NPT 57″ X 34″ X 80″ 2100 LBS
    CFD-30W 30 TONS 15 X 2 407C 5 72 57 134 @ 230V / 67 @ 460V 2″ NPT 57″ X 34″ X 80″ 2200 LBS
    CFD-40W 40 TONS 20 X 2 407C 7.5 92 61 178 @ 230V / 89 @ 460V 2 1/2″ NPT 57″ X 34″ X 80″ 2500 LBS
                         
  • Array ( [0] => new-equipment [1] => temp-controlchillers [2] => new-equipment [3] => temp-controlchillers )
  • WATER COOLED 5 TO 40 TONS


    Water Cooled Portable Chillers 5 to 40 Tons

    Process liquid chillers are designed to circulate a fluid medium (typically water, or a water-glycol solution) through a process application for cooling and can supply temperatures between 20° to 65°F. These units can service a single or multiple cooling points, and are designed to be moved between process applications as the need requires. Generally, portable liquid chillers are offered in capacities from ¼ to 40 tons.

    Water cooled liquid chillers use a plant water supply source (tower water, city water, or well water) to dissipate process heat. Major benefits to water-cooled units are less capital expense and less maintenance.

    FEATURES 5 TO 40 TON UNITS

    REFRIGERANT CIRCUITS:
    • Scroll compressors
    • Shell-in-tube water-cooled condenser
    • Refrigerant sight glass with moisture indicator
    • Filter-drier
    • Liquid line solenoid valve
    • Thermostatic expansion valve
    • Brazed plate evaporator

    COOLANT CIRCUIT:
    • High Flow Centrifugal pump
    • Large capacity insulated non-ferrous reservoir
    • Reservoir level sight glass
    • Automatic water make-up system
    • Standard NPT process fittings

    PRESSURE GAUGES:
    • Refrigerant high pressure
    • Refrigerant low pressure
    • Coolant pressure

    ELECTRICAL:
    • Process pump motor starter
    • Compressor motor contactor
    • Fused transformer
    • Nema rated electrical cabinet
    • Power entry terminal block

    SYSTEM LIMIT DEVICES:
    • High pressure limit
    • Low pressure limit
    • Coolant freezestat
    • Process pump motor overload
    • Internal compressor overload
    • Control circuit fuse

    WARRANTIES:
    • 1 year on parts and labor

    CONTROLLER 5 TO 40 TON UNITS

    M1 Series (standard instrument)
    • Continuous To Process temperature display
    • Selectable Setpoint temperature display
    • Illuminate ON/OFF power switch
    • Soft touch Setpoint selection keys
    • Bright and easy-to-read LCD Temperature
    display window
    • Machine Status with Compressor and
    Capacity Control indicating lights
    • Basic Machine Diagnostics
    with Refrigeration
    Fault indicating light

    ALL MODELS WATER COOLED, HERMETIC SCROLL COMPRESSOR, AND USE STAINLESS STEEL CONSTRUCTED CENTRIFUGAL PUMPS. 5 TO 10 TON UNITS HAVE 25 GALLON HOLDING TANK AND 15 TO 40 TON UNITS HAVE 65 GALLON HOLDING TANK – ALL ARE STANDARD WITH TANK LID – DIMESIONS ARE HEIGHT X WIDTH X DEPTH

    MODEL CAPACITY REFRIDGERANT NEEDED CONDENSOR GPM CITY/TOWER REQUIRED GPM (3-PHASE) FL AMPS 230V / 460V CONNECTIONS DIMENSIONS WEIGHT
    MW-5 5 TONS R410A 8 / 15 13 25 @ 230V / 12.5 @ 460V 1 1/4″ NPT 52″ X 24″ X 62″ 450 LBS
    MW-7.5 7.5 TONS R410A 12 / 23 22 31 @ 230V / 16 @ 460V 1 1/4″ NPT 52″ X 24″ X 62″ 525 LBS
    MW-10 10 TONS R410A 15 / 30 28 43 @ 230V / 22 @ 460V 1 1/4″ NPT 52″ X 24″ X 62″ 545 LBS
    MW-15 15 TONS R410A 23 / 45 36 60 @ 230V / 30 @ 460V 2″ NPT 52″ X 24″ X 70″ 845 LBS
    MW-20 20 TONS R410A 30 / 60 47 84 @ 230V / 42 @ 460V 2″ NPT 52″ X 24″ X 70″ 885 LBS
    MW-25 25 TONS R407C 38 / 75 60 104 @ 230V / 52 @ 460V 2 1/2″ NPT 57″ X 29″ X 70″ 1040 LBS
    MW-30 30 TONS R407C 45 / 90 72 120 @ 230V / 60 @ 460V 2 1/2″ NPT 57″ X 29″ X 70″ 1100 LBS
    MW-40 40 TONS R407C 60 / 120 101 156 @ 230V / 78 @ 460V 2 1/2″ NPT 57″ X 36″ X 84″ 1200 LBS
  • Array ( [0] => new-equipment [1] => temp-controlchillers [2] => new-equipment [3] => temp-controlchillers )
  • WATER COOLED 1 TO 3 TONS


    Water Cooled Portable Chillers 1 to 3 Tons

    Process liquid chillers are designed to circulate a fluid medium (typically water, or a water-glycol solution) through a process application for cooling and can supply temperatures between 20° to 65°F. These units can service a single or multiple cooling points, and are designed to be moved between process applications as the need requires. Generally, portable liquid chillers are offered in capacities from ¼ to 40 tons.

    Water cooled liquid chillers use a plant water supply source (tower water, city water, or well water) to dissipate process heat. Major benefits to water-cooled units are less capital expense and less maintenance.

    FEATURES 1 TO 3 TON UNITS

    REFRIGERANT CIRCUITS:
    • Scroll compressors
    • Tube-in-tube Water-cooled condenser
    • Refrigerant sight glass with moisture indicator
    • Filter-drier
    • Liquid line solenoid valve
    • Thermostatic expansion valve
    • Brazed plate evaporator

    COOLANT CIRCUIT:
    • High Flow Centrifugal pump
    • Large capacity insulated non-ferrous reservoir
    (no tank lid offered on this model).
    • Reservoir level sight glass
    • Automatic water make-up system
    • Standard NPT process fittings

    PRESSURE GAUGES:
    • Refrigerant high pressure
    • Refrigerant low pressure
    • Coolant pressure

    ELECTRICAL:
    • Process pump motor starter
    • Compressor motor contactor
    • Fused transformer
    • Nema rated electrical cabinet
    • Power entry terminal block
    • Factory installed 10′ power cord

    SYSTEM LIMIT DEVICES:
    • High pressure limit
    • Low pressure limit
    • Coolant freezestat
    • Process pump motor overload
    • Internal compressor overload
    • Control circuit fuse

    WARRANTIES:
    • 1 year on parts and labor

    CONTROLLER 1 TO 3 TON UNITS

    M1 Series (standard instrument)
    • Continuous To Process temperature display
    • Selectable Setpoint temperature display
    • Illuminate ON/OFF power switch
    • Soft touch Setpoint selection keys
    • Bright and easy-to-read LCD Temperature
    display window
    • Machine Status with Compressor and
    Capacity Control indicating lights
    • Basic Machine Diagnostics
    with Refrigeration
    Fault indicating light

    ALL UNITS ARE WATER COOLED, USE STAINLESS STEEL CONSTRUCTED CENTRIFUGAL PUMPS, AND HAVE 7 TO 7.5 GALLON HOLDING TANK – TANK LID IS OPTIONAL

    MODEL CAPACITY COMPRESSOR HP REFRIDGERANT PUMP HP GPM PSI (3-PHASE) FL AMPS 230V / 460V CONNECTIONS DIMENSIONS WEIGHT
    CF-1W 1 TON 1 410A 1/2 2.4 60 22 @ 115V SINGLE PHASE ONLY 3/4″ NPT 30″ X 37″ X 24″ 445 LBS
    CF-2W 2 TONS 2 410A 3/4 4.8 32 16 @ 230V / 8 @ 460V 3/4″ NPT 30″ X 37″ X 24″ 460 LBS
    CF-3W 3 TONS 3 410A 3/4 7.2 30 18 @ 230V / 9 @ 460V 3/4″ NPT 30″ X 37″ X 24″ 470 LBS
  • Array ( [0] => new-equipment [1] => temp-controlchillers [2] => new-equipment [3] => temp-controlchillers )
  • AIR COOLED 5 TO 30 TONS


    Air Cooled Portable Chillers 5 to 30 Tons

    Process liquid chillers are designed to circulate a fluid medium (typically water, or a water-glycol solution) through a process application for cooling and can supply temperatures between 20° to 65°F. These units can service a single or multiple cooling points, and are designed to be moved between process applications as the need requires. Generally, portable liquid chillers are offered in capacities from ¼ to 40 tons.

    Air-cooled liquid chillers use ambient air to dissipate process heat. These units efficiently run in plant air temperatures between 60° to 95°F. Major benefits to air-cooled units are heat recovery (for supplemental heating), exhaust air ducting (for plant ventilation), and less operating expense.

    FEATURES 5 TO 30 TON UNITS

    FRAME CONSTRUCTION:
    • Powder coated steel upright frame
    • Galvanized steel cross frame
    • Powder coated steel lift-off cabinetry
    • Lift-off top panel
    • Thermoformed ABS front fascia
    • Compact physical size
    • Castors – for portability

    REFRIGERANT CIRCUITS:
    • Scroll compressors
    • Air-cooled condenser with finned tubes
    • Propeller fan(s) induced air flow
    • Refrigerant sight glass with moisture indicator
    • Filter-drier
    • Liquid line solenoid valve
    • Thermostatic expansion valve
    • Brazed plate evaporator

    COOLANT CIRCUIT:
    • High Flow Centrifugal pump
    • Large capacity insulated non-ferrous reservoir
    • Reservoir level sight glass
    • Automatic water make-up system
    • Standard NPT process fittings

    PRESSURE GAUGES:
    • Refrigerant high pressure
    • Refrigerant low pressure
    • Coolant pressure

    ELECTRICAL:
    • Process pump motor starter
    • Compressor motor contactor
    • Fused transformer
    • Nema rated electrical cabinet
    • Power entry terminal block

    SYSTEM LIMIT DEVICES:
    • High pressure limit
    • Low pressure limit
    • Coolant freezestat
    • Process pump motor overload
    • Internal compressor overload
    • Control circuit fuse

    WARRANTIES:
    • 1 year on parts and labor

    CONTROLLER 5 TO 30 TON UNITS

    M1 Series (standard instrument)
    • Continuous To Process temperature display
    • Selectable Setpoint temperature display
    • Illuminate ON/OFF power switch
    • Soft touch Setpoint selection keys
    • Bright and easy-to-read LCD Temperature
    display window
    • Machine Status with Compressor and
    Capacity Control indicating lights
    • Basic Machine Diagnostics
    with Refrigeration
    Fault indicating light

    OPTIONS

    REFRIGERANT CIRCUIT:
    • Compressor CPR valve (for setpoints above 65°F)

    COOLANT CIRCUIT:
    • Overhead piping kit : factory or field installed
    • No reservoir tank for gravity return applications
    • Low flow bypass valve : manual or automatic
    • Process line shut-off valves
    • Larger process pumps

    SYSTEM SAFETY DEVICES:
    • Audible alarm
    • Visual / audible alarm
    beacon

    WARRANTIES:
    • Extended compressor
    warranty

    AF MODELS FAN COOLED, AB MODELS BLOWER COOLED, ALL MODELS USE STAINLESS STEEL CONSTRUCTED CENTRIFUGAL PUMPS, 5 TO 10 TON UNITS HAVE 25 GALLON HOLDING TANK AND 15 TO 30 TON UNITS HAVE 65 GALLON HOLDING TANK – ALL ARE STANDARD WITH TANK LID – DIMENSIONS ARE HEIGHT X WIDTH X DEPTH

    MODEL CAPACITY COMP HP REFRIDGERANT CONDENSOR CFM REQUIRED GPM @ 20 PSI (3-PHASE) FL AMPS 230V / 460V CONNECTIONS DIMENSIONS WEIGHT
    MA-5A 5 TONS 5 410A 2 X 1/3 HP FANS 5000 12 28.2 @ 230V / 13 @ 460V 1 1/4″ NPT 60″ X 34″ X 40″ 800 LBS
    MA-7.5A 7.5 TONS 7.5 410A 2 X 1/2 HP FANS 7500 18 39.7 @ 230V / 20.6 @ 460V 1 1/4″ NPT 60″ X 34″ X 40″ 900 LBS
    MA-10A 10 TONS 10 410A 2 X 3/4 HP FANS 10000 24 57.3 @ 230V / 28.7 @ 460V 1 1/4″ NPT 60″ X 34″ X 56″ 1000 LBS
    MA-15A 15 TONS 15 410A 2 X 7.5 HP BLOWERS 15000 36 90.6 @ 230V / 45.3 @ 460V 1 1/4″ NPT 60″ X 64″ X 56″ 1640 LBS
    MA-15FC 15 TONS 15 410A 2 X 7.5 HP FANS 15000 36 90.6 @ 230V / 45.3 @ 460V 1 1/4″ NPT 60″ X 64″ X 56″ 1640 LBS
    MA-20A 20 TONS 20 410A 2 X 10 HP BLOWERS 20000 48 119 @ 230V / 59.5 @ 460V 1 1/2″ NPT 102″ X 58″ X 70″ 1950 LBS
    MA-20FC 20 TONS 20 410A 2 X 10 HP FANS 20000 48 119 @ 230V / 59.5 @ 460V 1 1/2″ NPT 102″ X 58″ X 70 1950 LBS
    MA-25A 25 TONS 25 410A 1 – 15 HP BLOWER 25000 60 146 @ 230V / 73 @ 460V 2″ NPT 102″ X 58″ X 70 2050 LBS
    MA-30A 30 TONS 30 410A 1 – 20 HP BLOWER 30000 60 179 @ 230V / 89.5 @ 460V 3″ NPT 102″ X 58″ X 70 2250 LBS
  • Array ( [0] => new-equipment [1] => temp-controlchillers [2] => new-equipment [3] => temp-controlchillers )
  • AIR COOLED 2 TO 4 TONS


    Air Cooled Portable Chillers 2 to 4 Tons

    Process liquid chillers are designed to circulate a fluid medium (typically water, or a water-glycol solution) through a process application for cooling and can supply temperatures between 20° to 65°F. These units can service a single or multiple cooling points, and are designed to be moved between process applications as the need requires. Generally, portable liquid chillers are offered in capacities from ¼ to 40 tons.

    Air-cooled liquid chillers use ambient air to dissipate process heat. These units efficiently run in plant air temperatures between 60° to 95°F. Major benefits to air-cooled units are heat recovery (for supplemental heating), exhaust air ducting (for plant ventilation), and less operating expense.

    FEATURES 2 TO 4 TON UNITS

    FRAME CONSTRUCTION:
    • Stainless steel sheet metal
    • Lift-off top
    • Compact physical size
    • Castors – for portability

    REFRIGERANT CIRCUITS:
    • Hermetic compressors
    • Air-cooled condenser with finned tubes
    • Propeller fan(s) induced air flow
    • Refrigerant sight glass with moisture indicator
    • Filter-drier
    • Liquid line solenoid valve
    • Thermostatic expansion valve
    • Brazed plate evaporator

    COOLANT CIRCUIT:
    • High Flow Centrifugal pump
    • Large capacity insulated non-ferrous reservoir
    (no tank lid offered on this model).
    • Reservoir level sight glass
    • Standard NPT process fittings

    PRESSURE GAUGES:
    • Refrigerant high pressure
    • Refrigerant low pressure
    • Coolant pressure

    ELECTRICAL:
    • Process pump motor starter
    • Compressor motor contactor
    • Fused transformer
    • Nema rated electrical cabinet
    • Power entry terminal block

    SYSTEM LIMIT DEVICES:
    • High pressure limit
    • Low pressure limit
    • Coolant freezestat
    • Process pump motor overload
    • Internal compressor overload
    • Control circuit fuse

    WARRANTIES:
    • 1 year on parts and labor

    1/4 Ton to 1.5 Ton Unit Pictured Below

    2 Ton to 4 Ton Unit Pictured Below

    CONTROLLER 2 TO 4 TON UNITS

    M1 Series (standard instrument)
    • Continuous To Process temperature display
    • Selectable Setpoint temperature display
    • Illuminate ON/OFF power switch
    • Soft touch Setpoint selection keys
    • Bright and easy-to-read LCD Temperature
    display window
    • Machine Status with Compressor and
    Capacity Control indicating lights
    • Basic Machine Diagnostics
    with Refrigeration
    Fault indicating light

    OPTIONS

    REFRIGERANT CIRCUIT:
    • Compressor CPR valve
    (for setpoints above 65°F)

    COOLANT CIRCUIT:
    • Overhead piping kit : factory
    or field installed
    • No reservoir tank for
    gravity return applications
    • Low flow bypass valve :
    manual or automatic
    • Process line shut-off valves
    • Larger process pumps

    SYSTEM SAFETY DEVICES:
    • Audible alarm
    • Visual / audible alarm
    beacon

    WARRANTIES:
    • Extended compressor
    warranty

    ALL UNITS ARE FAN COOLED, USE STAINLESS STEEL CONSTRUCTED CENTRIFUGAL PUMPS, 2 & 3 TON UNITS HAVE 7.5 GALLON TANK & 4 TON UNIT HAS 25

    MODEL CAPACITY COMPRESSOR HP REFRIDGERANT PUMP HP GPM PSI (3-PHASE) AMPS 230V / 460V CONNECTIONS DIMENSIONS WEIGHT
    CF2A 2 TONS 2 410A 3/4 4.8 32 17 @ 230V / 8.5 @ 460V 3/4″ NPT 30″ X 37″ X 24″ 415 LBS
    CF3A 3 TONS 3 410A 3/4 7.2 30 20 @ 230V / 10 @ 460V 1″ NPT 43″ X 34″ X 40″ 600 LBS
    CF4A 4 TONS 4 410A 3/4 9.6 30 24 @ 230V / 12 @ 460V 1 1/4″ NPT 60″ X 34″ X 40″ 800 LBS
  • Array ( [0] => new-equipment [1] => temp-controlchillers [2] => new-equipment [3] => temp-controlchillers )
  • AIR COOLED .25 TO 1.5 TONS


    Air Cooled Portable Chillers 1/4 to 1.5 Tons

    Process liquid chillers are designed to circulate a fluid medium (typically water, or a water-glycol solution) through a process application for cooling and can supply temperatures between 20° to 65°F. These units can service a single or multiple cooling points, and are designed to be moved between process applications as the need requires. Generally, portable liquid chillers are offered in capacities from ¼ to 40 tons.

    Air-cooled liquid chillers use ambient air to dissipate process heat. These units efficiently run in plant air temperatures between 60° to 95°F. Major benefits to air-cooled units are heat recovery (for supplemental heating), exhaust air ducting (for plant ventilation), and less operating expense.

    FEATURES 1/4 TO 1.5 TON UNITS

    FRAME CONSTRUCTION:
    • Stainless steel sheet metal
    • Lift-off top
    • Compact physical size
    • Castors – for portability

    REFRIGERANT CIRCUITS:
    • Hermetic compressors
    • Air-cooled condenser with finned tubes
    • Propeller fan(s) induced air flow
    • Refrigerant sight glass with moisture indicator
    • Filter-drier
    • Liquid line solenoid valve
    • Thermostatic expansion valve
    • Coaxial evaporator

    COOLANT CIRCUIT:
    • Brass vane pump
    • Large capacity insulated non-ferrous reservoir
    (no tank lid offered on this model).
    • Reservoir level sight glass
    • Standard NPT process fittings

    ELECTRICAL:
    • Process pump motor starter
    • Compressor motor contactor
    • Fused transformer
    • Nema rated electrical cabinet
    • Power entry terminal block
    • Factory installed 10′ power cord

    SYSTEM LIMIT DEVICES:
    • High pressure limit
    • Low pressure limit
    • Coolant freezestat
    • Internal compressor overload
    • Control circuit fuse

    WARRANTIES:
    • 1 year on parts and labor

    1/4 Ton to 1.5 Ton Unit Pictured Below

    2 Ton to 4 Ton Unit Pictured Below

    CONTROLLER 1/4 TO 1.5 TON UNITS

    • Continuous To Process temperature display
    • Selectable Setpoint temperature display
    • Illuminate ON/OFF power switch
    • Soft touch Setpoint selection keys
    • Bright and easy-to-read LCD emperature display
    • Machine Status with Compressor and Capacity
    Control indicating lights
    • Basic Machine Diagnostics with Refrigeration Fault
    indicating light

    OPTIONS

    REFRIGERANT CIRCUIT:
    • Compressor CPR valve (for setpoints above 65°F)

    COOLANT CIRCUIT:
    • Overhead piping kit : factory or field installed
    • No reservoir tank for gravity return applications
    • Low flow bypass valve : manual or automatic
    • Process line shut-off valves
    • Larger process pumps

    SYSTEM SAFETY DEVICES:
    • Audible alarm
    • Visual / audible alarm
    beacon

    WARRANTIES:
    • Extended compressor
    warranty

    ALL UNITS ARE FAN COOLED, USE BRASS CONSTRUCTED POSITIVE DISPLACEMENT PUMPS, HAVE A 4 GALLON HOLDING TANK CAPACITY WITH TANK LID

    MODEL CAPACITY COMPRESSOR HP REFRIDGERANT PUMP HP GPM PSI (SINGLE PHASE) AMPS 115V / 230V CONNECTIONS DIMENSIONS WEIGHT
    CF.25A .29 TONS .25 134A 1/3 .7 60 13 @ 115V / 230V NOT AVAILABLE 1/2″ NPT 33″ X 18″ X 24″ 220 LBS
    CF.33A .39 TONS .33 134A 1/3 .9 60 15 @ 115V / 230V NOT AVAILABLE 1/2″ NPT 33″ X 18″ X 24″ 220 LBS
    CF.5A .50 TONS .50 134A 1/3 1.2 60 17 @ 115V / 9 @ 230V 1/2″ NPT 33″ X 18″ X 24″ 220 LBS
    CF.75A .75 TONS .75 134A 1/3 1.8 60 21 @ 115V / 11 @ 230V 1/2″ NPT 33″ X 18″ X 24″ 265 LBS
    CF-1A 1 TONS 1 134A 1/2 2.4 60 29 @ 115V / 15 @ 230V 1/2″ NPT 37″ X 19″ X 25″ 345 LBS
    CF-1.5A 1.5 TONS 1.5 134A 1/2 3.6 60 115V NOT AVAILABLE / 20 @ 230V 1/2″ NPT 37″ X 19″ X 25″ 350 LBS

  • Array ( [0] => new-equipment [1] => temp-controlchillers [2] => new-equipment [3] => temp-controlchillers )
  • VTO Heat Series


    Oil Media VTO Series Heating Only Temperature Control

    Temperature control units circulate a fluid medium (typically water or oil) through a process application for HEATING can supply temperatures between 30° to 400°F (depending on medium). Temperature controller units service only a single process at a time, but are designed to be moved between process applications as the need requires.

    A pump circulates high temperature oil through the process. An electric heater elevates the temperature of the oil. Cooling is achieved through ambient radiation or through the use of an optional heat exchanger. Units are available microprocessor control instrument, several heater KW ratings, and several optional cooling heat exchanger sizes.

    UNIT CONSTRUCTION
    • All galvanized sheet metal cabinetry
    • Upright design
    • Easy access lift-off panel
    • Hinged electrical panel
    • Portable, on casters
    • NPT female process connections

    CIRCULATING PUMP
    • Horizontal centrifugal pump
    • Water cooled pump seal (prolongs seal life)
    • ODP motor with high temperature bearings
    • Stainless steel motor shaft
    • Brass impeller
    • 500¾F carbon/niresist shaft seal
    • Custom cast pump casing accepts heater cycliner

    HEATING
    • Flanged bolt-in mount
    • Vertical orientation
    • Steel heater sheath
    • Mercury heater contactor

    ELECTRICAL
    • Nema 1 style electrical construction
    • 3 Phase service
    • 110 volt control circuit transformer
    • Control circuit fusing.

    LIMITS
    • Water supply pressure switch
    • Water supply pressure relief valve
    • Motor overload protection
    • Dual high temperature limits
    • Fused control circuit

    OPTIONS
    • Stainless steel heat exchanger for cooling

    WARRANTIES
    • 1 year parts and labor warranty

    CONTROLLER

    The VTO Series microprocessor control instrument offers stable process temperatures at setpoint, analog setpoint selection with machine status monitoring.

    Designed exclusively for Temptek hot oil temperature control units, the VTO Series Control is built on a microprocessor circuit design to offer functional simplicity to the process environment.

    TEMPERATURE DISPLAY:
    Bright 9-segment 3 digit display window that is easy to read at distance.

    CONTROL RANGE:
    100° – 400°F (38° – 202°C) control range.

    OPERATORS: The On/Off switch activates the unit. Setpoint temperature is selected by the analog selection dial

    INDICATORS: Operating status is indicated by the Power, Pump, Heat and Cool lights.

    WARRANTY: 1 year free replacement.

    MODEL HEATER HP GPM PSI AMPS @ 230V AMPS @ 460V PROCESS CONNNECTIONS SUPPLY/DRAIN CONNECTIONS DIMENSIONS WEIGHT
    VTO2100H 12 KW 1 30 24 34.8 17.9 1″ NPT 1/2″ NPT 44″ X 16″ X 24″ 275 LBS
    VTO2150H 12 KW 1 1/2 45 26 36.4 18.7 1″ NPT 1/2″ NPT 44″ X 16″ X 24″ 285 LBS
    VTO2200H 12 KW 2 50 28 38.0 19.5 1″ NPT 1/2″ NPT 44″ X 16″ X 24″ 300 LBS
    VTO2300H 12 KW 3 60 26 46.6 23.3 1″ NPT 1/2″ NPT 44″ X 16″ X 24″ 290 LBS
    VTO3100H 16 KW 1 30 24 50.6 25.4 1″ NPT 1/2″ NPT 44″ X 16″ X 24″ 580 LBS
    VTO3150H 16 KW 1 1/2 45 26 47.0 23.5 1″ NPT 1/2″ NPT 44″ X 16″ X 24″ 585 LBS
    VTO3200H 16 KW 2 50 28 49.0 24.5 1″ NPT 1/2″ NPT 44″ X 16″ X 24″ 595 LBS
    VTO3300H 16 KW 3 60 26 21.0 25.5 1″ NPT 1/2″ NPT 44″ X 16″ X 24″ 610 LBS
    VTO4100H 24 KW 1 30 24 73.8 36.9 1″ NPT 1/2″ NPT 44″ X 16″ X 24″ 625 LBS
    VTO4150H 24 KW 1 1/2 45 26 75.8 37.9 1″ NPT 1/2″ NPT 44″ X 16″ X 24″ 630 LBS
    VTO4200H 24 KW 2 50 28 77.8 38.9 1″ NPT 1/2″ NPT 44″ X 16″ X 24″ 635 LBS
    VTO4200H 24 KW 3 60 26 71.0 35.5 1″ NPT 1/2″ NPT 44″ X 16″ X 24″ 645 LBS
  • Array ( [0] => new-equipment [1] => temp-controlchillers [2] => new-equipment [3] => temp-controlchillers )
  • LX Series


    Water Media LX Series Temperature Control

    Temperature control units circulate a fluid medium (typically water or oil) through a process application for HEATING can supply temperatures between 30° to 400°F (depending on medium). Temperature controller units service only a single process at a time, but are designed to be moved between process applications as the need requires.

    A pump circulates water through the process. An electric heater and a cooling valve work together to control the water temperature. Theses units are portable and require a plant water supply source and are available with a variety of different control instruments, heater sizes, and cooling valves.

    UNIT CONSTRUCTION:
    • All stainless sheet metal cabinetry
    • Upright design
    • Easy access lift-off panel
    • Twin tank design
    • Hinged electrical panel
    • Portable, on casters

    CIRCULATING PUMP
    • Centrifugal type
    • Custom cast pump casing for
    increased flow
    • Bronze impeller
    • Energy efficient pump motor
    • Stainless steel motor shaft
    • Overload relay protection
    • Pump seal flush

    HEATING
    • Custom cast heater cylinder
    • Dual voltage heater
    • Flanged, bolt-in mount
    • Mercury contactor

    COOLING
    • Custom cast cooling cylinder
    • Modulating valve
    • 0 to 100% aperture range
    • Microprocessor controlled
    • Integral to cooling tank
    • Field serviceable

    ELECTRICAL
    • Fused transformer
    • 10′ power cord,
    factory installed

    LIMITS
    • Water supply pressure switch
    • Pressure relief valve
    • High temperature limit
    • Fused control circuit

    WARRANTIES:
    • 1 year on parts and labor

    CONTROLLER

    TEMPERATURE DISPLAYS:
    Bright 9-segment 3 digit displays window that are easy to read at distance. The upper window shows To Process temperature. The lower window shows Setpoint temperature.

    CONTROL RANGE:
    30° – 250°F (0° – 120°C) control range.

    OPERATORS: The On/Off switch activates the unit. Setpoint temperature and other operating parameters are selected by the two soft key Arrow buttons. Unit Vent is activated by the Vent key.

    INDICATORS: Operating status is indicated by the Power, Pump, Heat and Cool lights.

    DIAGNOSTICS: Unit diagnostics is indicated by the Safety and Alarm lights. See manual for troubleshooting details.

    COMMUNICATIONS: Network communications is provided via the RS-422 port.

    WARRANTY: 2 year free replacement.

    MODEL HEATER HP GPM PSI AMPS @ 230V AMPS @ 460V PROCESS CONNNECTIONS SUPPLY/DRAIN CONNECTIONS DIMENSIONS WEIGHT
    VT275LX 10 KW 3/4 35 30 27.8 13.9 1 1/4″ NPT 1/2″ NPT 27″ X 11″ X 16″ 200 LBS
    VT2100LX 10 KW 1 45 30 28.6 14.3 1 1/4″ NPT 1/2″ NPT 27″ X 11″ X 16″ 208 LBS
    VT2150LX 10 KW 1.5 62 30 30.2 15.1 1 1/4″ NPT 1/2″ NPT 27″ X 11″ X 16″ 208 LBS
    VT2200LX 10 KW 2 75 30 31.8 15.9 1 1/4″ NPT 1/2″ NPT 27″ X 11″ X 16″ 213 LBS
    VT2300LX 10 KW 3 80 30 34.6 17.3 1 1/4″ NPT 1/2″ NPT 27″ X 11″ X 16″ 223 LBS
    VT375LX 16 KW 3/4 35 30 42.8 21.4 1 1/4″ NPT 1/2″ NPT 27″ X 11″ X 16″ 205 LBS
    VT3100LX 16 KW 1 45 30 43.6 21.8 1 1/4″ NPT 1/2″ NPT 27″ X 11″ X 16″ 210 LBS
    VT3150LX 16 KW 1.5 62 30 45.2 22.6 1 1/4″ NPT 1/2″ NPT 27″ X 11″ X 16″ 210 LBS
    VT3200LX 16 KW 2 75 30 48.8 23.4 1 1/4″ NPT 1/2″ NPT 27″ X 11″ X 16″ 220 LBS
    VT3300LX 16 KW 3 80 30 49.6 24.8 1 1/4″ NPT 1/2″ NPT 27″ X 11″ X 16″ 225 LBS