Water Media LS Series Temperature Control
Temperature control units circulate a fluid medium (typically water or oil) through a process application for HEATING can supply temperatures between 30° to 400°F (depending on medium). Temperature controller units service only a single process at a time, but are designed to be moved between process applications as the need requires.
A pump circulates water through the process. An electric heater and a cooling valve work together to control the water temperature. Theses units are portable and require a plant water supply source and are available with a variety of different control instruments, heater sizes, and cooling valves.
UNIT CONSTRUCTION:
• All stainless sheet metal cabinetry
• Upright design
• Easy access lift-off panel
• Twin tank design
• Hinged electrical panel
• Portable, on casters
CIRCULATING PUMP
• Centrifugal type
• Custom cast pump casing for
increased flow
• Bronze impeller
• Energy efficient pump motor
• Stainless steel motor shaft
• Overload relay protection
• Pump seal flush
HEATING
• Custom cast heater cylinder
• Dual voltage heater
• Flanged, bolt-in mount
• Mercury contactor
COOLING
• Custom cast cooling cylinder
• Solenoid valve, integral to
cooling cylinder
• Microprocessor controlled
ELECTRICAL
• Fused transformer
• 10′ power cord,
factory installed
LIMITS
• Water supply pressure switch
• Pressure relief valve
• High temperature limit
• Fused control circuit
WARRANTIES:
• 1 year on parts and labor
CONTROLLER
• TEMPERATURE DISPLAYS:
Bright 9-segment 3 digit displays window that are easy to read at distance. The upper window shows To Process temperature. The lower window shows Setpoint temperature.
• CONTROL RANGE:
30° – 250°F (0° – 120°C) control range.
• OPERATORS: The On/Off switch activates the unit. Setpoint temperature and other operating parameters are selected by the two soft key Arrow buttons. Unit Vent is activated by the Vent key.
• INDICATORS: Operating status is indicated by the Power, Pump, Heat and Cool lights.
• DIAGNOSTICS: Unit diagnostics is indicated by the Safety and Alarm lights. See manual for troubleshooting details.
• COMMUNICATIONS: Network communications is provided via the RS-422 port.
• WARRANTY: 2 year free replacement